• 官方二维码
欢迎进入红领巾瓜报官网!
当前位置:首页 - 新闻中心 - 行业资讯

行业资讯

燃气发电机组停机要做好哪些防护?

返回 2023.03.02 来源: 0
1、卸载:
1. Uninstall:
燃气发电机组停机前,要先卸去负荷。
Before the gas generator unit is shut down, the load shall be removed first.
2、怠速运行:
2. Idle running:
额定转速下运行几分钟,初步冷却后,再将怠速/额定转换开关置于&濒诲辩耻辞;怠速&谤诲辩耻辞;位置,使机组怠速运行.使其水温和油温降下来。
Run for several minutes at rated speed, and after preliminary cooling, set the idle/rated transfer switch to the "idle" position to make the unit run at idle speed, and lower its water temperature and oil temperature.
3、切断气源:
3. Cut off the air supply:
当机组&濒诲辩耻辞;水温&谤诲辩耻辞;、降低到60℃以下后,关闭手动燃气阀门。剩余的燃气可使机组继续运行1、2分钟,燃气耗尽后,机组将自动停机。
When the "water temperature" of the unit drops below 60 ℃, close the manual gas valve. The remaining gas can keep the unit running for 1 or 2 minutes. After the gas is exhausted, the unit will stop automatically.
注意:
be careful:

燃气发电机组
对于配置增压器的机组,水温、油温降至60℃时不能接着关气、停机,应再空载运行5分钟,使增压器进一步冷却。否则会造成增压器漏油。
For the unit equipped with supercharger, when the water temperature and oil temperature drop to 60 ℃, the unit cannot be shut down and shut down again. It should be operated for another 5 minutes without load to further cool the supercharger. Otherwise, the supercharger will leak oil.
4、停机后,将控制屏面板上的钥匙关毕。
4. After shutdown, turn off the key on the control panel.
5、除发生飞车或工作场所出现易燃气等意外事故,正常情况下严禁带负荷停机。
5. It is strictly prohibited to stop with load under normal conditions except for accidents such as speeding or flammable gas in the workplace.
6、若停车后需要长期封存,应将机组的冷却水和机油放净,将机组表面处理干净,相关部位涂抹封存油,以免零件锈蚀。
6. If long-term sealing is required after shutdown, the cooling water and oil of the unit shall be drained, the surface of the unit shall be cleaned, and the relevant parts shall be coated with sealing oil to prevent parts from rusting.
7、紧急停机。正常运行的燃气发电机组,未按正常停机步骤停机都属于紧急停机。主要有两种情况:
7. Emergency stop. The gas generator unit in normal operation that fails to shut down according to the normal shutdown steps belongs to emergency shutdown. There are two main situations:
(1)发电机组因超速、油压低等故障原因,自行报警停机。
(1) The generator unit will automatically alarm and shut down due to overspeed, low oil pressure and other fault reasons.
(2)在使用过程中,遇到危及人身及设备稳定的紧急情况时,发电运行人员按下&濒诲辩耻辞;紧急停车&谤诲辩耻辞;按钮,人为机组停车。紧急停机的处理措施:切断电源,用盘车工具人力盘转曲轴,同时用手动机油泵泵油,带机组水温、油温降至60℃以下后,在进行检查处理
(2) In the process of use, in case of emergency endangering the stability of personnel and equipment, the power generation operator presses the "emergency stop" button to manually stop the unit. Treatment measures for emergency shutdown: cut off the power supply, manually turn the crankshaft with the turning tool, and pump oil with the hand motor. After the water temperature and oil temperature of the unit drop below 60 ℃, check and handle
新闻搜索
红领巾瓜报
  • 服务热线

    0531-62325028
    0531-69951266

燃气发电机组停机要做好哪些防护?

1、卸载:
1. Uninstall:
燃气发电机组停机前,要先卸去负荷。
Before the gas generator unit is shut down, the load shall be removed first.
2、怠速运行:
2. Idle running:
额定转速下运行几分钟,初步冷却后,再将怠速/额定转换开关置于&濒诲辩耻辞;怠速&谤诲辩耻辞;位置,使机组怠速运行.使其水温和油温降下来。
Run for several minutes at rated speed, and after preliminary cooling, set the idle/rated transfer switch to the "idle" position to make the unit run at idle speed, and lower its water temperature and oil temperature.
3、切断气源:
3. Cut off the air supply:
当机组&濒诲辩耻辞;水温&谤诲辩耻辞;、降低到60℃以下后,关闭手动燃气阀门。剩余的燃气可使机组继续运行1、2分钟,燃气耗尽后,机组将自动停机。
When the "water temperature" of the unit drops below 60 ℃, close the manual gas valve. The remaining gas can keep the unit running for 1 or 2 minutes. After the gas is exhausted, the unit will stop automatically.
注意:
be careful:

燃气发电机组
对于配置增压器的机组,水温、油温降至60℃时不能接着关气、停机,应再空载运行5分钟,使增压器进一步冷却。否则会造成增压器漏油。
For the unit equipped with supercharger, when the water temperature and oil temperature drop to 60 ℃, the unit cannot be shut down and shut down again. It should be operated for another 5 minutes without load to further cool the supercharger. Otherwise, the supercharger will leak oil.
4、停机后,将控制屏面板上的钥匙关毕。
4. After shutdown, turn off the key on the control panel.
5、除发生飞车或工作场所出现易燃气等意外事故,正常情况下严禁带负荷停机。
5. It is strictly prohibited to stop with load under normal conditions except for accidents such as speeding or flammable gas in the workplace.
6、若停车后需要长期封存,应将机组的冷却水和机油放净,将机组表面处理干净,相关部位涂抹封存油,以免零件锈蚀。
6. If long-term sealing is required after shutdown, the cooling water and oil of the unit shall be drained, the surface of the unit shall be cleaned, and the relevant parts shall be coated with sealing oil to prevent parts from rusting.
7、紧急停机。正常运行的燃气发电机组,未按正常停机步骤停机都属于紧急停机。主要有两种情况:
7. Emergency stop. The gas generator unit in normal operation that fails to shut down according to the normal shutdown steps belongs to emergency shutdown. There are two main situations:
(1)发电机组因超速、油压低等故障原因,自行报警停机。
(1) The generator unit will automatically alarm and shut down due to overspeed, low oil pressure and other fault reasons.
(2)在使用过程中,遇到危及人身及设备稳定的紧急情况时,发电运行人员按下&濒诲辩耻辞;紧急停车&谤诲辩耻辞;按钮,人为机组停车。紧急停机的处理措施:切断电源,用盘车工具人力盘转曲轴,同时用手动机油泵泵油,带机组水温、油温降至60℃以下后,在进行检查处理
(2) In the process of use, in case of emergency endangering the stability of personnel and equipment, the power generation operator presses the "emergency stop" button to manually stop the unit. Treatment measures for emergency shutdown: cut off the power supply, manually turn the crankshaft with the turning tool, and pump oil with the hand motor. After the water temperature and oil temperature of the unit drop below 60 ℃, check and handle