燃气发电机组动力不足现象的原因
燃气发电机组排出的冷却水和废气中的热量通过热回收装置进行回收后,作为燃气发生器的加温热源。燃气发电机组功力不足故障原因及排除方法,介绍!
The heat in the cooling water and exhaust gas discharged from the gas generator unit is recycled by the heat recovery device and used as the heating source of the gas generator. The causes and troubleshooting methods of insufficient power of gas generator set are introduced!
一、燃气发电机组燃气系统故障
1、 Gas system failure of gas generator unit
1、燃气气压低,供气量不足
1. Low gas pressure and insufficient gas supply
2、燃气质量差,有效成分低
2. Poor gas quality and low effective composition
3、燃气道堵塞
3. Gas duct blocked
4、混合器膜片有裂缝
4. Cracks in the diaphragm of the mixer
解决方法:
resolvent:
1、提高气压
1. Increase air pressure
2、增大燃气进气量
2. Increase gas intake
3、清理、更换膜片
3. Clean and replace the diaphragm
二、燃气发电机组进、排系统故障:比正常情况下排温较高、烟色较差
2、 Fault of gas generator unit inlet and exhaust system: higher exhaust temperature and worse smoke color than normal
1、空气滤清器阻塞
1. Air filter clogged
2、排气管阻塞或接管过长、转弯半径太小,弯头太多
2. The exhaust pipe is blocked or the connecting pipe is too long, the turning radius is too small, and there are too many elbows
解决方法:
resolvent:
清洗空气滤清器芯子或清除纸质滤芯上的灰尘,必要时应更换
Clean the air cleaner core or remove the dust on the paper filter element, and replace it if necessary
清理排气管内积碳:重装排气接管,弯头不能多于叁个,并有足够大的排气截面
Clean the carbon deposit in the exhaust pipe: reinstall the exhaust pipe, with no more than three elbows and sufficient exhaust cross-section
叁、燃气发电机组进、排气相位变动;各档转速下性能变差
3、 The inlet and exhaust phases of the gas generator set change; Poor performance at various speeds
解决方法
resolvent
进行配气相位和气门间隙检查
Check the valve timing and valve clearance