发电机组气缸套水温过高或过低的原因
如果燃气发电机组气缸套的温度过高或过低,控制模块会发出气缸套水温高或水温低的警报,原因是什么呢?
If the temperature of the cylinder liner of the gas generator set is too high or too low, the control module will give an alarm of high or low water temperature of the cylinder liner. What is the reason?
缸套水温高的原因为:
The reasons for the high water temperature of the cylinder liner are:
漏水或损耗过大而导致缸套水不足;散热水箱积尘较多,或风扇出现故障无法散热;节温器出现故障;缸套的水温度传感器或电路出现故障;超过负荷范围;具体诊断方法为:对散热水箱电机的运行状况进行检查,及时更换故障电机如发现水箱散热片出现堵塞及时进行水箱的清理;及时更换故障节温器;对缸套水温度传感器进行故障检测,并对电路回路予以判断,及时进行更换与维修处理;降低负荷。
Insufficient cylinder liner water due to water leakage or excessive loss; There is too much dust in the cooling water tank, or the fan fails to dissipate heat; Failure of thermostat; Water temperature sensor or circuit of cylinder liner is faulty; Exceeding the load range; The specific diagnosis methods are as follows: check the operation condition of the motor of the cooling water tank, replace the faulty motor in time, and clean the water tank in time if the radiator of the water tank is found to be blocked; Timely replace the faulty thermostat; Detect the fault of cylinder liner water temperature sensor, judge the circuit circuit, and replace and repair it in time; Reduce the load.
缸套水温度较低的原因:
Reasons for lower cylinder liner water temperature:
加热器出现故障;缸套水温度传感器或电路发生故障;节温器未正常开启;具体诊断方法为:检测加热器温控开关是否正常开启,并对停机继电器的运行进行检查,及时进行配件更换;排查传感器及电器回路;检查节温器是否存在故障。
Heater failure; Cylinder liner water temperature sensor or circuit fault; The thermostat is not normally opened; The specific diagnosis methods are as follows: check whether the temperature control switch of the heater is normally opened, check the operation of the shutdown relay, and replace the parts in time; Check the sensor and electrical circuit; Check whether the thermostat is faulty.
故障诊断的步骤:
Steps for fault diagnosis:
通过机组的配套贰罢对有关参数进行检查,对于发生故障发生机组所有异常现象掌握清楚,并进行以下问题的分析与查证:
Check the relevant parameters through the matching et of the unit, master all abnormal phenomena of the unit in case of failure, and analyze and verify the following problems:
查阅检修记录,燃气发电机组经过哪些相关的维修或保养;是否曾经发生过相似的故障,是怎样解决的;机组的运行环境是否有变化
Check the maintenance records and find out the relevant maintenance or repair of the gas generator unit; Whether similar faults have occurred and how to solve them; Is there any change in the operating environment of the unit
在对机组故障进行诊断的基础上,对造成故障的原因进行具体分析以确定故障发生具体部位。
On the basis of unit fault diagnosis, the cause of the fault is analyzed to determine the specific location of the fault.
在故障定位以后,对相关的部位和部件进行检查,以确定故障发生的具体原因并采取排除措施。
After the fault is located, relevant parts and components shall be inspected to determine the specific cause of the fault and take troubleshooting measures.
This is the reason why the water temperature of the cylinder liner of the generator set is too high or too low and the relevant diagnosis method. You can use it as a reference. For more relevant information, please visit our website Get it.